Tel : +86-577-62665555
+86-577-62668988
Business Email : [email protected]
CM1 Series of moulded case circuit breaker
Detailed description
Brief description
CM1moulded case circuit breaker with rated insulation voltage800V, applied in the power system of AC50(60)Hz, rated voltage 690V and below, rated current 1250A and below as the transfer not frequently. The circuit breaker has the protection devices of over load, short circuit and under voltage ,it can protect the circuit and power equipment from broken.
The mccb can be sorted to C type (basic),L type (standard),M type (high breaking), H type(higher breaking) according to its rated limit short circuit breaking capacity.
The mccb has the features small volume, breaking capacity high, electric arcing short ,anti-vibration. It is the ideal product for application in land and ship.
The installation can be vertical or level and the standard conforms to IEC60947-2 and GB14048.2
Technical parameters
Model |
RatedCurrent(A) |
PolesRated |
RatedInsulationVoltage(V) |
RatedVoltage(V) |
ElectricArcingDistance(mm) |
RatedLimitShort?circuitBreakingCapacity(KA) |
RatedWorkingShort-circuitBreakingCapacity(KA) |
O?performancePerformance?(Times)On-power?Offpowe |
|
CM163L |
6,10, 16,20, 25,32, 40,50, 63 |
2,3,4 | 800 | 400 | 0 | 25 | 18 | 6000 | 8500 |
CM1-63M |
690v and below
|
50 | 35 | ||||||
CM1-100C |
10,16, 20,25, 32,40, 50,63, 80,100 |
25 | 18 | ||||||
CM1-100L | 0(<=50) | 35 | 22 | ||||||
CM1-100M | 50 | 35 | |||||||
CM1-100H | 85 | 50 | |||||||
CM1-225C |
100,125, 140,160, 180,200, 225 |
400 |
<=50 | 25 | 18 | 2000 | 7000 | ||
CM1-225L | 35 | 22 | |||||||
CM1-225M | 50 | 35 | |||||||
CM1-225H | 85 | 50 | |||||||
CM1-400C |
225,250, 315,350, 400 |
35 | 25 | 1000 | 4000 | ||||
690v and below |
|||||||||
CM1-400L | 50 | 35 | |||||||
CM1-400M | <=100 | 65 | 42 | ||||||
CM1-630C |
400,500, 630 |
35 | 25 | ||||||
CM1-630L | 50 | 35 | |||||||
CM1-630M | 65 | 42 | |||||||
CM1-630H | 100 | 65 | |||||||
CM1-800M |
630,700, 800 |
75 | 50 | 1000 | 2500 | ||||
CM1-800H | 100 | 65 | |||||||
CM1-1250H |
800,1000, 1250 |
<=120 | 100 | 65 | 1000 | 2000 |
Shell Parameters
Shell current Inm |
63 | 125 | 250 | |||||||||||||
Frequency (f) |
50/60HZ | |||||||||||||||
Rated insulation voltage (V) |
AC690 | AC800 | AC800 | |||||||||||||
Rated impact tolerance voltage (KV) |
6 | 8 | 8 | |||||||||||||
Rated working voltage | AC400/415V | AC400/415V/690V | AC400/415V/690V | |||||||||||||
Capability level | L | L | M | M | L | L | M | M | M | H | L | L | M | M | M | H |
Poles | 3 | 4 | 3 | 4 | 3 | 4 | 2 | 3 | 4 | 3 | 3 | 4 | 2 | 3 | 4 | 3 |
Rating limit short circuit breaking capacity Icu(KA) |
25 | 25 | 50 | 50 | 35 | 35 | 50 | 50 | 50 | 85 | 35 | 35 | 50 | 50 | 50 | 85 |
Rated operation short circuit breaking capacity/Ics(KA) |
18 | 15 | 30 | 30 | 26 | 20 | 30 | 30 | 30 | 43 | 26 | 20 | 30 | 30 | 30 | 43 |
Mechanical life | 8500 | 8500 | 7000 | |||||||||||||
Electrical life | 1500 | 1000 | ||||||||||||||
Arc distance(MM) | 50 | |||||||||||||||
Tripping device / rated current | ||||||||||||||||
Thermal magnetic fixation / rated current(A) | 10/16/20/25/32/40/50/63 | 10/16/20/25/32/40/50/63/80/100/125 | 100/125/160/180/200/225/250 | |||||||||||||
Shape size (mm)L-W-H1-H2 |
3pole (M type) | 4pole (M type) | 2pole (M type) | 3pole (M type) | 4pole (M type) | 2pole (M type) | 3pole (M type) | 4pole (M type) | ||||||||
135-76-82-100 | 135-101-82-100 | 150-65-87-103.5 | 150-92-87-103.5 | 150-122-87-103.5 | 165-74-104-124.5 | 165-107-104-124.5 | 165-142-104-124.5 | |||||||||
Shape size
(mm)L-W-H1-H2 |
3pole (L type) | 4pole (L type) | 2pole (L type) | 3pole (L type) | 4pole (L type) | 2pole (L type) | 3pole (L type) | 4pole (L type) | ||||||||
135-76-73-95 | 135-101-73-95 | N | 150-92-68-87 | 150-122-68-87 | N | 165-107-87-108 | 165-142-87-108 |